For those that need to disable all users at the locks during the COVID-19 crisis and don't want to allow anyone access to a room/building, the easiest way is to use the DISABLE/ENABLE ALL functions 6 & 7 at the locks keypad. This function will disable all users except the master code.
To do this, first put the lock into program mode using the Master code only.
Master Code then AL button
Wait for the beeps to stop then:
AL button then the number 6 then the Star button. This will DISABLE all users except the master code.
After the crisis is over, use Function 7 to ENABLE all user again.
Master code then AL button
Wait for the beeps to stop then:
AL button then the number 7 then the Star button.
If you have unlock (Passage) schedules in the lock and you want to disable all schedules, then use the Function 49. This will lock the door and override all schedules in the lock.
Master code then the AL button
Wait for the beeps to stop then:
AL button then 49 then the Star button. This will lock the door and override all unlock (Passage) schedules.
To turn the unlock schedules back on:
Master code then the AL button
Wait for the beeps to stop then:
AL button then 50 then the Star button. This will enable all unlock (Passage) schedules.